Easykon Lite for MyHome compatible gateways

In this article you will find:

MyHome gateways compatible with Easykon Lite for MyHome

To access and automatically identify the compatible devices present on the BTicino system, Easykon Lite for MyHome must use a compatible BTicino gateway device.

The BTicino gateway devices compatible with Easykon Lite for MyHome are:
  • MH200
  • MH200N
  • MH201
  • MH202
  • MH4892
  • MH4892C
  • MH4893
  • MH4893C
  • F450
  • F453
  • F453AV
  • F454
  • F455
  • F458
  • F459
  • H/L4684
  • MyHomeServer1

Make sure your BTicino gateway has the latest released firmware version before connecting Easykon Lite for MyHome.

Gateway setup

To connect to the MyHome BTicino system, Easykon Lite for MyHome use a compatible BTicino gateway.

You can use 3 different methods to setup your compatible BTicino gateway:

All the gateways can use the Open password, for the other 2 methods, check the configuration of your module.

Use the open password

To set the password in the compatible BTicino gateway:
  1. Open MyHomeSuite
  2. Open the system project or create a new one
  3. Select the BTicino device that you want to use to connect Easykon to your plant or add one new, make sure it is the same model you have on your system
  4. Open the gateway configuration (double click on the name) and select “Authentication”
  5. In the “Automatic system” area, under the option “Password security open” select “Low security”
  6. At the option “Password OPEN” it will appear the default password “12345”, you can use that one or modify it. Use the password you set as open password when you connect Easykon Lite for MyHome to the compatible BTicino gateway

You can use the open password with all the BTicino gateway compatible with Easykon Lite for MyHome.

You can download the configuration software for the BTicino gateway, free of charge from the BTicino site, in MyHomeSuite page.

Use HMAC password

To set the HMAC password:
  1. Open MyHomeSuite
  2. Open the system project or create a new one
  3. Select the BTicino device that you want to use to connect Easykon to your plant or add one new, make sure it is the same model you have on your system
  4. Open the gateway configuration (double click on the name) and select “Authentication”
  5. In the “Automatic system” area, under the option “Password security open” select “High security (HMAC)”
  6. Create the open password and use it when you are connecting Easykon Lite for MyHome to your compatible BTicino gateway.

You can download the configuration software for the BTicino gateway, free of charge from the BTicino site, in MyHomeSuite page.

Set up the correct IP range

To set up the correct IP range on the BTicino gateway compatible with Easykon Lite for MyHome:
  1. Open MyHomeSuite
  2. Open the system project or create a new one
  3. Select the BTicino device that you want to use to connect Easykon to your plant or add one new, make sure it is the same model you have on your system
  4. Open the gateway configuration (double click on the name) and select  “IP adresses enabled”
  5. Within the “IP address range 1” area, select “Yes” from the “Enable” option
  6. Save and send the configuration

You can download the configuration software for the BTicino gateway, free of charge from the BTicino site, in MyHomeSuite page.